πŸ“ Attic Size & Existing Insulation
Sets the recommended attic target below. Zones are assigned by county (IECC Table R301.1), and several states span more than one, so check your county, not your state.
ft
ft
sq ft
Footprint of the ceiling below, not the roof surface
in
Measure in three or four spots and use the average, not the deepest
R
Auto-filled with your zone’s recommended R-value (ENERGY STAR and the 2021 IECC agree) β€” override it freely
Blown-in covers better over uneven, obstructed attics
Bag charts differ several-fold between products. Pick the one you are buying, or type its figure below.
sq ft
Filled from the chart chosen above when you calculate. To use your own bag, choose β€˜I will type the figure’ and look up the R you are ADDING
βœ“ Results
Attic floor area 1,200 sq ft
Recommended target for your zone R-60
R-value you already have about R-13 (5 in at R-2.5/in)
R-value still to add R-48
Additional depth to add 13.6 in
Finished total depth 18.6 in
100 bags
Material to Buy
Coverage used 12 sq ft per bag (GreenFiber chart, R-49 row)
Rafter baffles for the eaves 60 baffles (approx)

Add about 13.6 in for R-48 more, finishing near 18.6 in deep. Confirm the 12 sq ft per bag figure on the bag chart at R-48, and check the minimum weight per square foot column too β€” blowing it fluffy hits the depth but not the R.

Insulating walls, floors or a cathedral ceiling as well?

Use our full Insulation Calculator β†’

How to Calculate Attic Insulation

Attic insulation at the eave Section through an attic at the eave. A sloping rafter and roof deck meet a horizontal ceiling joist above the exterior wall top plate. A baffle is fixed under the roof deck, holding an open channel from the soffit vent up into the attic. Insulation fills the attic floor to full depth away from the eave and tapers as it runs out over the top plate under the baffle. A ceiling penetration below is sealed before insulation is placed. depth Full depth here Baffle holds the vent path open tapers over the plate Soffit vent Ceiling penetration β€” air seal before insulating Exterior wall
Fig. 1 β€” The baffle holds an air path open from the soffit vent, so insulation can be pushed right out over the top plate instead of being held back to avoid blocking the vent. Air sealing happens first: once it is buried you cannot reach it.

Topping up an attic is different from insulating a bare one, because you are not buying the whole R-value β€” you are buying the difference between what is already there and what you want. Six inches of old blown fiberglass is already about R-15 (6 Γ— 2.5), so a zone 3 attic needs R-34 more, not the full R-49.

Existing R = existing depth Γ— R per inch of what is up there
R to add = Target R βˆ’ Existing R
Inches to add = R to add Γ· R per inch of the new material
Bags = Attic area Γ· sq ft per bag at the R you are adding

That makes the calculator an attic R-value calculator as well: it reports the R-value you already have, the R-value still to add, and how many inches of new material that takes.

Bags is the line people get wrong, because coverage per bag is not fixed: it shrinks as the R you are adding goes up.

There is no fixed square footage per bag. Coverage depends entirely on how deep you blow the material, because you are spreading a fixed weight of fiber over a variable area. GreenFiber’s 19 lb cellulose bag, for example, covers 36.7 sq ft at R-19 but only 12.0 sq ft at R-49. Every bag carries a printed coverage chart with a row for each R-value listing the minimum installed thickness, the maximum net coverage per bag, and the minimum weight per square foot. Look up the R-value you are ADDING β€” not your final target β€” and type that coverage figure into the calculator.

The minimum-weight column on that chart is the one nobody reads and the one that governs performance. Blowing the material too fluffy hits the depth without hitting the density, and the insulation settles below rated R within a year or two.

Measuring the attic

On this page

  1. How to Calculate Attic Insulation
  2. Attic R-Value Targets by Climate Zone
  3. How Much Insulation Do I Need in My Attic?
  4. Identifying What Is Already Up There
  5. Bags of Blown-In: What the Coverage Chart Says
  6. Do It In This Order
  7. Covering, Not Covering, and Older-Home Safety
  8. Frequently Asked Questions

Attic R-Value Targets by Climate Zone

The attic is the highest-return insulation in almost any house: heat rises, the assembly is accessible, and the material is cheap. These are the ranges the US Department of Energy and ENERGY STAR publish for existing homes, with the higher end reflecting what recent IECC editions require for new construction. Codes vary by state and change every few cycles, so confirm with your local building department if the job is permitted or tied to a rebate.

ZoneRepresentative CitiesRecommended Attic RRough Depth, Blown CelluloseRough Depth, Blown Fiberglass
1Miami, Honolulu, Key WestR-309 in12 in
2Houston, Orlando, Phoenix, New OrleansR-4914 in20 in
3Atlanta, Charlotte, Dallas, Los AngelesR-4914 in20 in
4Nashville, Washington DC, Kansas City, SeattleR-6017 in24 in
5Chicago, Denver, Boston, DetroitR-6017 in24 in
6Minneapolis, Burlington, HelenaR-6017 in24 in
7Duluth, Fargo, interior AlaskaR-60 or more17 in +24 in +

Depths above use R-3.5 per inch for cellulose and R-2.5 per inch for blown fiberglass β€” reasonable working figures, but check the chart on the product you buy. Zone 8, the far north of Alaska, treats R-60 as a floor rather than a target.

Diminishing returns are real, but they arrive later than people think. Going from R-11 to R-30 is a large, obvious change in comfort and bills. R-30 to R-49 is a smaller but still worthwhile gain. R-49 to R-60 is marginal in a mild climate and clearly worth it in zone 5 and colder. What is never marginal is the air sealing underneath β€” that is where the first big win lives, and it costs a fraction of the insulation.

How Much Insulation Do I Need in My Attic?

Enough to reach R-49 in climate zones 2 and 3, R-60 in zones 4 and north, and R-30 in zone 1. In blown-in material that is roughly 14 in of cellulose or 20 in of fiberglass for R-49, and 17 or 24 in for R-60. Measure what is already up there, convert it to R, and buy only the difference.

For a bare attic, the bag count comes straight off the product chart: attic floor area divided by the square feet one bag covers at your target R. Using two of the charts in the coverage section below:

Attic Floor AreaR-49: Cellulose BagsR-49: AttiCat BagsR-60: Cellulose BagsR-60: AttiCat Bags
1,000 sq ft842611232
1,500 sq ft1253816748
2,000 sq ft1675122363

Cellulose is GreenFiber in a 19 lb bag (12 sq ft per bag at R-49, 9 at R-60); AttiCat is Owens Corning blown fiberglass in a 27.5 lb bag (39.9 and 31.8 sq ft). Counts are rounded up to whole bags. Fiberglass bags go several times further by area, so never use a cellulose count to buy fiberglass or the other way round.

Most attics are a top-up, not a bare start. A 1,200 sq ft attic with 5 in of old blown fiberglass already has about R-13; reaching R-60 means adding about R-48, which is 13.6 in of cellulose. At the R-49 line of the GreenFiber chart (12 sq ft per bag) that is 100 bags. Enter your own numbers in the calculator above. Its Coverage Source setting reads these charts for you, rounding up to the next chart row, or you can type the figure from the bag you are buying.

The targets are ENERGY STAR’s recommendations for existing homes. Your local code enforcement office can tell you what applies where you live, and what it says overrides any figure here.

Identifying What Is Already Up There

You need two things about the existing layer: what it is, and how deep it is. Identification matters because R per inch varies by nearly a factor of two between materials, and because two of the possibilities are reasons to stop work.

Looks LikeMaterialR per InchWhat To Do
Loose, fluffy, white, yellow or pink; almost weightlessBlown fiberglassR-2.2 to R-2.9, older product at the low endBlow straight over it
Grey shredded paper, slightly dusty, denserBlown celluloseR-3.2 to R-3.8Blow straight over it
Neat rectangles between joists, often kraft-facedFiberglass battsR-3.0 to R-4.3Add unfaced batts across the joists, or blow over
Dark, dense, gritty, holds its shapeLoose-fill mineral woolR-3.0 to R-3.3Blow straight over it
Loose grey-brown pebbles, accordion-shaped, shiny flecksVermiculiteR-2.1 to R-2.7STOP. Test for asbestos before touching it
Ceramic knobs, cloth-covered wire in porcelain tubesKnob-and-tube wiringn/aSTOP. Must be replaced before burying
White or grey wrapping on ducts and pipesPossible asbestos laggingn/aLeave alone, get it assessed

Measure the real depth. Push a ruler down through the material until it touches the ceiling drywall. Do this near the middle of the attic, halfway out, and about 4 ft in from the eaves, then average. Older blown jobs settle 10 to 20% over their first few years, so what looks like R-19 is frequently performing like R-15.

A note on old batts. If the existing batts are compressed, sagging, damaged by rodents, or wet, they no longer deliver their rated R. Wet insulation in particular loses almost all its value and points at a roof leak that needs fixing before anything else happens up there β€” our roofing calculator is the next stop if that is what you find.

Bags of Blown-In: What the Coverage Chart Says

The coverage chart is a table on the side of every bag of loose-fill insulation. It typically has four columns: R-value, minimum installed thickness, maximum net coverage per bag, and minimum weight per square foot. There will also be a "bags per 1,000 sq ft" figure, which is the same information stated the other way round.

The figures below are three real products’ published attic charts: GreenFiber cellulose in a 19 lb bag, Johns Manville Climate Pro blown fiberglass, and Owens Corning AttiCat blown fiberglass in a 27.5 lb bag. Coverage per bag differs several-fold between products and bag sizes, so they are examples, not a substitute for the chart on the bag you are holding β€” which is why the calculator lets you pick the chart for your product, or type the figure from your own bag, rather than assuming one.

In both tables below, A is GreenFiber cellulose (19 lb bag), B is Johns Manville Climate Pro blown fiberglass, and C is Owens Corning AttiCat blown fiberglass (27.5 lb bag).

Square Feet Covered per Bag

R-Value Being AddedA: CelluloseB: JM Climate ProC: AttiCat
R-1356176169.8
R-1937119110.7
R-30227368.5
R-38165752.6
R-49124339.9
R-6093431.8

Settled Depth (Inches)

R-Value Being AddedA: CelluloseB: JM Climate ProC: AttiCat
R-133.94.95
R-195.67.07
R-308.610.810.75
R-3810.813.413.5
R-4913.716.917
R-6016.520.220.5

Owens Corning’s AttiCat fact sheet puts the rule plainly: the stated R-value comes from installing the required number of bags at no less than the minimum thickness, and falling short on either gives a lower R-value. The same holds for every product in the table.

Two practical consequences:

Do not add a waste factor to blown-in. Unlike sheet goods, a partial bag is not wasted and the chart already accounts for settled density. Buy what the math says plus one or two bags, and return the unopened extras.

Batts in an attic top-up go on unfaced and perpendicular to the joists, laid across the tops so they break the thermal bridge the joists create. Never use faced batts for the second layer β€” the facing between two layers of insulation is a vapor trap in exactly the wrong place.

Will the Ceiling Hold It? Weight per Square Foot

Divide a bag’s weight by the area it covers and you get what the insulation puts on each square foot of ceiling. From the two charts that give a bag weight:

R-ValueCellulose (GreenFiber, 19 lb bag)Blown Fiberglass (AttiCat, 27.5 lb bag)
R-300.86 lb/sq ft0.40 lb/sq ft
R-381.19 lb/sq ft0.52 lb/sq ft
R-491.58 lb/sq ft0.69 lb/sq ft
R-602.11 lb/sq ft0.86 lb/sq ft

Cellulose at R-60 weighs about two and a half times as much as fiberglass at the same R. That load sits on the ceiling drywall between the framing, and the limit depends on the board’s thickness and the framing spacing. Thin board on framing 24 in apart is the case to check: gypsum board makers and the Gypsum Association publish how much insulation a ceiling board can carry, and sag-resistant ceiling board exists for exactly this. Before blowing a deep layer of cellulose over 24 in framing, check the board maker’s limit or ask your local code enforcement office.

Do It In This Order

The sequence matters more than the product choice. Everything on this list becomes unreachable the moment insulation goes down, so front-load the work that can only be done once.

To compare doing it yourself with hiring it out, the attic insulation cost guide lists planning ranges for each material.

  1. Inspect first, on a cool morning. Look for roof leak stains on the underside of the deck, rodent activity, disconnected bath fan ducts, and any wiring that looks pre-1950. Fix leaks before insulating, always.
  2. Air seal the big holes. Open chases around chimneys and flues, dropped soffits above kitchen cabinets, the tops of interior partition walls, and the gap around plumbing stacks. These few openings leak more than every small penetration combined. Use rigid material plus fire-rated sealant at flues, never expanding foam against a metal flue.
  3. Seal the small penetrations. Wiring holes, ceiling boxes, recessed can housings, bath fan bodies. Caulk or low-expansion foam.
  4. Confirm every exhaust fan and dryer duct terminates outdoors. A bath fan dumping into the attic will soak whatever you install over it.
  5. Weatherstrip and insulate the hatch or pull-down stair. An uninsulated 10 sq ft hatch is a hole straight through your R-60.
  6. Staple a baffle into every rafter bay along the eaves. Not a few β€” every one. They keep the soffit-to-ridge air path open and stop loose fill washing into the soffit.
  7. Dam anything that must stay uncovered: non-IC-rated recessed lights, knob-and-tube runs, and a 3 in clearance around masonry chimneys and B-vent flues. Sheet metal or rigid board, not cardboard.
  8. Mark the target depth. Staple rulers or write the depth on the rafters at several points before you start. Depth is impossible to judge by eye once the attic is white.
  9. Lay walk boards. Once the joists are buried you cannot see where to step, and a foot through the ceiling is an easy accident to have.
  10. Blow from the far corner back toward the hatch, keeping the hose moving so density stays even. Two people is far easier than one β€” someone feeding the hopper, someone on the hose.
  11. Check depth as you go against your markers, and top up the thin spots at the end.

Covering, Not Covering, and Older-Home Safety

What you cover

What you never cover

Ventilation still has to work

Adding insulation makes the attic colder in winter, which is the entire point β€” but it also means the attic has less heat available to dry it out. If ventilation is marginal, more insulation can turn a dry attic into a damp one. The usual rule of thumb is 1 sq ft of net free vent area per 150 sq ft of attic floor, halved to 1 in 300 when there is a proper vapor retarder or when the vents are split roughly evenly between soffit and ridge. Balance matters more than total: intake at the soffits should at least equal exhaust at the ridge, or the attic will pull its make-up air from the house through every gap you failed to seal.

Older homes: check before you start

In a house built before roughly 1980, identify three things before any work begins:

None of these should stop a project permanently. All three should stop it for a phone call.

Protect yourself

Wear an N95 or better, sealed goggles, gloves, and long sleeves taped at the wrists. Work in the cool part of the day β€” attic temperatures in summer are dangerous, and heat exhaustion up there is far more common than any fiber exposure. Keep the hatch open for airflow, take breaks, and shower in cool water afterwards; hot water opens skin pores and drives fibers in. Once the insulation is done and the ceilings need patching, our drywall calculator and drywall mud calculator cover the repair side.

Frequently Asked Questions

How many bags of insulation do I need for my attic?

Divide the attic floor area by the coverage per bag listed on the bag at the R-value you are adding. A 1,200 sq ft attic adding R-38 with GreenFiber’s 19 lb cellulose, rated at 16.4 sq ft per bag at R-38, is about 74 bags. There is no universal number β€” coverage per bag falls as you blow deeper, so the chart on the bag is the only figure that counts.

How many bags of AttiCat insulation do I need?

Owens Corning’s AttiCat fact sheet (September 2019) lists bags per 1,000 sq ft for each R-value with its 27.5 lb bag: 14.6 at R-30, 19 at R-38, 25 at R-49 and 31.5 at R-60. An empty 1,200 sq ft attic taken to R-38 is 1.2 × 19 = 22.8, so about 23 bags, blown to at least 13.5 in. The sheet says you need both the bag count and the minimum thickness to get the stated R-value. Check the chart on your bags, since products are revised.

How deep should attic insulation be?

Depends on the material and your target. For R-49, plan on roughly 14 in of cellulose or 20 in of blown fiberglass. For R-60 it is about 17 in of cellulose or 24 in of blown fiberglass. Fiberglass batts run about 12 in for R-38 and 14 in or more for R-49. Mark the depth on the rafters before you blow β€” you cannot judge it by eye.

What R-value should my attic be?

R-30 in the deep south (zone 1), R-49 across the middle of the country (zones 2 and 3), and R-60 from zone 4 north. Those are ENERGY STAR’s current recommendations for an uninsulated attic, and the 2021 IECC sets the same three numbers for new homes. Local codes vary and change, so confirm with your building department if the work is permitted or tied to a utility rebate. If your attic is currently under R-30, almost any climate justifies topping it up.

Can I add new insulation over old insulation?

Yes, in most cases, and it is the normal way to do it. Blow loose fill straight over old fiberglass or cellulose, or lay unfaced batts across the joists. Two exceptions: do not add over insulation that is wet β€” find and fix the leak first β€” and do not add over vermiculite until it has been tested for asbestos.

Should attic insulation cover the joists?

Yes, once you are past joist depth. Wood conducts heat far better than insulation, so exposed joist tops are continuous thermal bridges across your ceiling β€” in a cold climate you can often see them as stripes in frost or melted snow on the roof. Burying them is the whole reason a second layer is laid perpendicular to the joists.

Should I air seal the attic before adding insulation?

Yes, before anything else. Insulation slows conductive heat flow; it does not stop air. Seal the big holes first β€” open chases, dropped soffits over cabinets, interior wall top plates, plumbing stacks β€” then the small ones. All of it becomes unreachable the moment insulation goes down.

Do I need baffles when I insulate an attic?

In a vented attic, yes β€” one in every rafter bay along the eave. Baffles hold the soffit-to-ridge air path open and stop loose fill washing forward into the soffit. Skip them and the attic loses its ability to dry, the roof deck stays damp, and in cold climates you get ice dams at the eaves. They cost a couple of dollars each and staple in with a hammer stapler.

Blown-in or batts for an attic?

Blown-in, in almost every case. It flows around wiring, ducts, bracing and irregular joist spacing, fills the awkward triangle at the eaves, and reaches high R without gaps. Batts only make sense in a small, clean, perfectly regular attic, or where you cannot get a blower hose in. Batts also depend entirely on install quality β€” a 5% gap around a batt costs far more than 5% of its R.

Cellulose or fiberglass for attic insulation?

Cellulose gives more R per inch (about R-3.5 versus R-2.5), packs denser so it resists air movement better, and is made from recycled paper treated with borate fire retardant. Blown fiberglass is lighter, does not absorb water, and each bag covers more area. If ceiling joists limit your depth, cellulose wins. If you have unlimited headroom and the price per R is lower, fiberglass is fine.

Can I cover recessed lights with attic insulation?

Only IC-rated housings, which are labeled as such inside the can. Non-IC housings need 3 inches of clearance on every side and covering one is a genuine fire risk. The cleanest fix is to replace old cans with airtight IC-rated LED housings before you insulate β€” usually cheaper than building dams and it seals a significant air leak at the same time.

Should attic insulation be faced or unfaced?

Unfaced whenever you are adding over existing insulation. A kraft or foil facing is a vapor retarder, and sandwiching one between two layers traps moisture inside the assembly. Faced batts are only appropriate as the first layer directly on the ceiling, with the facing down toward the heated space, and only in heating-dominated climates.

How do I measure my existing attic insulation?

Push a ruler straight down through the material until it hits the ceiling drywall, and read the depth. Do it in three or four spots β€” near the middle, halfway out, and about 4 ft in from the eaves β€” then average them. Insulation is always deepest in the center. Multiply the average depth by the material R per inch to estimate what you have: six inches of old blown fiberglass at about R-2.5 per inch is roughly R-15.

What if my attic has vermiculite insulation?

Stop and have it tested. Vermiculite β€” loose, pebbly, grey-brown granules, often branded Zonolite β€” largely came from a mine whose ore was contaminated with asbestos. Do not disturb it, sweep it, vacuum it, or blow insulation over it until a lab confirms what it is. Testing is inexpensive relative to the risk, and abatement is a licensed job, not a weekend one.

Does attic insulation settle over time?

It depends on the product, and the coverage chart tells you. GreenFiber’s cellulose chart lists an installed thickness about 10% above the settled thickness at every R-value (11.97 in installed for 10.77 in settled at R-38), so you blow it deeper than the target. Owens Corning’s AttiCat fiberglass sheet lists the same installed and settled thickness. Either way, both charts say you need the minimum number of bags and the minimum thickness: blown too fluffy, insulation can reach the depth with too few bags and fall short of its R-value. Batts are not blown, so these charts do not apply to them.

Sources & Standards

Estimates for planning only. The figures here follow published model codes and industry standards, but those are adopted and amended locally, and older buildings are often legally exempt from the current edition. Check with your local code enforcement office or building department before you order or build β€” they are the authority that inspects the work, and what they require overrides anything on this page. See our full method and assumptions.

Last updated Β· How we calculate