Need the trim to go with it?
Use the trim and baseboard calculator →On this page
Nominal, Actual and Coverage — the Number That Matters
A board has three widths, and ordering off the wrong one is an easy mistake to make.
- Nominal is the name on the label — a "1×6".
- Actual is what it measures after milling and drying. A 1×6 is 5-1/2 in. That much is a published standard.
- Coverage is what you can see once the tongue or the lap is hidden inside the next board — about 5 in for a 1×6.
Order a 14 × 8 ft wall off the nominal 6 in and you buy about 17% too little. Order off the actual 5-1/2 in and you are still about 9% short. Only the coverage width gives the right number, and it is the one figure that is not on the label.
| Nominal | Actual Width | Typical Coverage | Lost to the Lap |
|---|---|---|---|
| 1 × 4 | 3-1/2 in | about 3 to 3-1/4 in | 7 to 14% |
| 1 × 6 | 5-1/2 in | about 5 to 5-1/4 in | 5 to 9% |
| 1 × 8 | 7-1/4 in | about 6-3/4 to 7 in | 3 to 7% |
| 1 × 10 | 9-1/4 in | about 8-3/4 to 9 in | 3 to 5% |
The actual widths above are a standard and do not vary. The coverage figures are typical and do vary — the profile, the lap depth and the manufacturer all move it, and a nickel-gap board deliberately leaves a gap that a plain tongue-and-groove board does not. The real number is printed on the bundle or the manufacturer's page. Use the Custom option and put it in; it is worth the thirty seconds.
Why Sheets Are Counted Differently From Planks
The calculator counts sheets and planks two different ways on purpose, and the two will not agree. That is correct.
Planks are divided by area, because a board cut short at the end of one row starts the next row. Offcuts get used, so subtracting a door from the area does reduce what you buy.
Sheets are counted across the wall, because a 4 ft panel is 4 ft of wall whatever you cut out of it. A 14 ft wall needs 14 ÷ 4 = 3.5 panels, so 4 panels — and a wall taller than the panel needs a second course, with the seam somewhere you have to live with. Dividing 91 sq ft of net wall by 32 sq ft per sheet gives 3, and 3 panels will not cover that wall.
This is the difference between paneling and drywall: gypsum gets cut, pieced and taped, so area division works. A visible seam in the middle of a finished panel is a defect, not a joint.
Board and Batten: Round the Bays, Not the Battens
Battens are the vertical boards; the spacing is measured center to center, and 12 to 24 in covers almost every job. Spacing is a matter of looks; it carries no load.
The end of the wall is where the arithmetic matters. The first and last battens sit tight in the corners, so the distance from the first center to the last is the wall length less one batten width. On a 14 ft wall with 2 1/2 in battens that is 168 − 2.5 = 165.5 in, and at 16 in on center it is 165.5 ÷ 16 = 10.3 bays. You cannot build a third of a bay, so round the bays to 10 and let the spacing land where it lands: 165.5 ÷ 10 = 16.55 in on center, a 14.05 in gap between battens, and 11 battens.
To lay them out, mark the left edge of each batten: 0, then 16.55 in, 33.1 in and so on, adding the real spacing each time. Measure every mark from the same corner rather than from the last batten, so small errors do not add up. The calculator lists the marks to the nearest 1/16 in, draws the wall, and gives a cut list. If you add a top or bottom rail, the battens get shorter by the rail’s width. Lay out one wall at a time, corner to corner, and add the walls up afterward: entering two walls as one long run puts a mark where the corner is and loses a batten.
Battens are not spliced, so the board count is whole boards: an 8 ft board gives one 7 ft 1 in batten with the offcut left over, and two battens only when each is 4 ft or less. A batten longer than the board needs a longer board. Rails run the full length of the wall and can be joined, so each takes the wall length divided by the board length, rounded up.
Round the battens instead and you finish with a narrow strip in one corner. If two walls meet and should look the same, run the longer wall first, note the spacing the calculator gives, and enter that spacing for the shorter wall; it will adjust only slightly.
Board and batten usually wants something behind it — either the existing drywall painted the same color, or a sheet backer. If you are sheeting behind it, run the sheet mode as well and add the two.
Before You Buy: Acclimation, Fasteners and Flame Spread
Let the material sit in the room first. Solid wood moves with humidity, and boards installed straight off the truck in winter will open gaps at every joint by summer. Three to five days stacked in the room it will live in, with air able to get around it, is the usual advice.
Fasteners have to reach the studs. Going over drywall is fine, but the nail has to land in framing, so mark the studs before you start and remember the drywall adds to the depth you need. Tongue-and-groove is normally blind-nailed through the tongue so nothing shows.
Buy it all at once. Anything with natural variation — and most wood paneling has it — will not match between batches.
Interior wall finishes are code-governed. Wall and ceiling finishes have to meet flame-spread and smoke-developed limits, and the requirements are considerably stricter for plastic and foam-backed panels than for solid wood. There are extra restrictions in particular places, including around fireplaces, in garages and along exit routes. Check with your local code enforcement office or building department before you buy the material — they are the authority that inspects it, and finding out after the wall is up means taking it back down.
Frequently Asked Questions
How do I calculate how much shiplap I need?
Work out the wall area, subtract the openings, then divide by the coverage width in feet — not the nominal width. A 14 × 8 ft wall with a 3 × 7 ft door is 91 sq ft net. With 1×6 shiplap covering about 5 in, that is 91 ÷ (5 ÷ 12) = 218 lineal feet, and 15% waste takes it to 252 lineal feet.
What is the difference between nominal, actual and coverage width?
Three different numbers for the same board, and ordering off the wrong one is an easy mistake to make. Nominal is the name — a "1×6". Actual is what it measures after milling, 5-1/2 in. Coverage is what it shows once the tongue or lap is hidden, about 5 in. Order off nominal and you are roughly 17% short; order off actual and you are about 9% short.
How many 4x8 sheets of paneling do I need?
Count them across the wall, not by dividing the area. A 14 ft wall needs 14 ÷ 4 = 3.5, rounded up to 4 sheets, and a wall over 8 ft tall needs a second course. Dividing 91 sq ft by 32 would say 3, which is wrong — you cannot reassemble the offcuts into a fourth panel without a visible seam.
Do I subtract doors and windows?
For planks yes — they are ordered by the foot and the offcuts get used further along the wall. For sheets, no: a sheet with a door cut out of it is still a sheet you bought. This calculator subtracts openings from the area and from the plank footage on a full-height wall, but counts sheets by the layout, which is why the two do not agree. Wainscot ignores the openings box, because it runs under the windows; doors cost it only a few feet, which the waste allowance absorbs. Board and batten ignores it too: the battens are laid out across the full wall, and any that land on a door or window are just cut shorter, so the count does not change.
How many battens for a board and batten wall?
Battens sit tight in each corner, so their centers span the wall length less one batten width. Divide that by the spacing for the number of bays, round it, and add one. A 14 ft wall (168 in) with 2 1/2 in battens at 16 in on center: (168 − 2.5) ÷ 16 = 10.3 bays, rounded to 10, so 11 battens. Rounding the bays rather than the battens is what keeps the spacing even — the real spacing is 165.5 ÷ 10 = 16.55 in on center, with a 14.05 in gap between battens. The calculator lists where to mark each one.
What spacing should board and batten be?
Anywhere from 12 to 24 in on center; spacing is a matter of looks, not structure. Narrower reads as traditional and busier; wider reads modern. Divide the wall evenly so you do not finish with a half bay in a corner — which is why the calculator rounds the bay count and tells you the spacing you end up with.
How high should wainscot be?
Usually 32 to 36 in to the top of the cap rail, which puts it at chair height. The other common approach is one third of the wall height — 32 in on an 8 ft wall. Going much past 48 in starts to read as full paneling rather than wainscot. A 14 ft wall at 36 in is 42 sq ft of material plus 14 lineal feet each of cap rail and baseboard.
How much waste should I allow for paneling?
10% on a simple square room, 15% where there are cuts and angles, 20% if the walls are busy or there is a grain or pattern to match. Planks want more than sheets because every row ends in a cut. If the boards are a natural material with visible variation, buy it all in one delivery — a second batch rarely matches.
Should shiplap run horizontally or vertically?
It changes the look, not the quantity — the same wall area needs the same footage either way. Horizontal is the familiar farmhouse look and makes a room read wider. Vertical makes a low ceiling look taller and sheds water better outdoors. Vertical boards need horizontal blocking or furring behind them if the studs run the same way.
Can I put paneling straight over drywall?
Usually yes, and it is the easiest route — the drywall gives you a flat substrate and the fasteners still need to reach the studs, so mark them first. Take the baseboard off rather than butting to it. If you are covering a wall that has no drywall, you need a substrate or blocking behind the boards; see the drywall calculator for that layer.
Is there a code issue with wall paneling?
There can be. Interior wall finishes are subject to flame-spread and smoke-developed limits, and the rules are stricter for plastic and foam panels than for solid wood. There are also restrictions in specific locations — around a fireplace, in a garage, or on the wall of an exit corridor. Check with your local code enforcement office or building department before you buy, particularly for anything foam-backed or plastic; they are the authority that inspects it.
What trim do I need with paneling?
Inside and outside corners, something at the top where the panel meets the ceiling, and baseboard at the floor. Sheet paneling usually wants a matching corner molding to hide the joint; planks can be mitered or butted to a corner board instead. Work the lineal footage out on the trim and baseboard calculator, which handles miters and corner counts.
Sources & Standards
- American Lumber Standard Committee — Softwood lumber nominal vs. dressed dimensions
- International Residential Code (ICC) — Residential construction requirements adopted by most US jurisdictions
Estimates for planning only. The figures here follow published model codes and industry standards, but those are adopted and amended locally, and older buildings are often legally exempt from the current edition. Check with your local code enforcement office or building department before you order or build — they are the authority that inspects the work, and what they require overrides anything on this page. See our full method and assumptions.