Pouring concrete steps rather than building them?
Use the Steps mode on our concrete calculator →On this page
How to Calculate Stair Rise and Run
Every stair comes from one measurement: the total rise, floor surface to floor surface. Everything else is division.
- Measure the total rise. Finished floor at the bottom to finished floor at the top. If the upper floor is not down yet, add its thickness now — a 3/4 in floor you forget turns every riser in the flight out by a fraction.
- Divide by your target riser. Total rise ÷ 7.5 in, rounded to a whole number, is your riser count. There is no such thing as a partial riser.
- Divide back for the real riser height. Total rise ÷ riser count. This is the number you mark out, and it will rarely be the round figure you aimed at.
- Check it against the limit. If the result is over 7-3/4 in, add one riser and divide again. A 48 in rise is the classic trap: six risers gives exactly 8.00 in, which is over the line, so it has to be seven.
- Treads are risers minus one. The top landing is the last tread.
- Total run = treads × tread depth. This is the floor length the stair eats.
The stringer itself is the hypotenuse: √(total rise² + total run²). For the 108 in rise above, that is √(108² + 130²) = 169 in, so a 14 ft board is short and you buy 16 ft.
Stair Code Limits You Have to Hit
Stairs are one of the few DIY jobs where the dimensions are not a matter of preference. These are the residential figures in the International Residential Code, which most US jurisdictions adopt with local amendments:
| Limit | IRC Residential Figure | Why It Bites |
|---|---|---|
| Maximum riser height | 7-3/4 in | The single number most home-built stairs fail on |
| Minimum tread depth | 10 in | Measured riser face to riser face, nosing excluded |
| Maximum riser variation in a flight | 3/8 in | Tallest minus shortest, which is why you divide evenly |
| Maximum tread variation in a flight | 3/8 in | Same reasoning as risers |
| Minimum stair width | 36 in | Clear width above the handrail height |
| Minimum headroom | 6 ft 8 in | Vertical, from the nosing line |
| Handrail height above nosing | 34–38 in | Required where there are four or more risers |
Confirm these against your own building department before cutting. Jurisdictions amend the IRC, older houses are often legal non-conforming, and an inspector signs off on the stair in front of them, not on a calculator. This tool flags numbers that fall outside the figures above; it cannot approve a design.
The riser variation limit is the one people underestimate. Three-eighths of an inch across the whole flight means you divide the rise evenly and cut every riser the same — you cannot absorb an error in the last step.
Common Stair Sizes
Worked out at a 7.5 in target riser and a 10 in tread. Every row is this calculator's own output, and every riser height below is inside the 7-3/4 in limit:
| Total Rise | Risers | Riser Height | Treads | Total Run | Stringer (min) | Board to Buy |
|---|---|---|---|---|---|---|
| 36 in (3 ft) | 5 | 7.20 in | 4 | 40 in | 53.8 in | 8 ft |
| 48 in (4 ft) | 7 | 6.86 in | 6 | 60 in | 76.8 in | 8 ft |
| 60 in (5 ft) | 8 | 7.50 in | 7 | 70 in | 92.2 in | 10 ft |
| 84 in (7 ft) | 11 | 7.64 in | 10 | 100 in | 130.6 in | 12 ft |
| 96 in (8 ft) | 13 | 7.38 in | 12 | 120 in | 153.7 in | 14 ft |
| 108 in (9 ft) | 14 | 7.71 in | 13 | 130 in | 169.0 in | 16 ft |
| 120 in (10 ft) | 16 | 7.50 in | 15 | 150 in | 192.1 in | 18 ft |
Notice the 48 in row. Rounding 48 ÷ 7.5 gives six risers at exactly 8.00 in, which is over the code limit, so the flight needs seven risers at 6.86 in instead. That single adjustment also adds 10 in of run. This is where a lot of home-built stairs go wrong, and it is invisible until an inspector puts a tape on it.
Cutting the Stringer
- Pick straight stock. A crowned or twisted board telegraphs into every tread. 2x12 is standard, because the cut-outs leave enough material behind them.
- Set a framing square to your riser height on one leg and your tread depth on the other, and clamp stair gauges there so every step repeats identically.
- Step the square down the board, marking riser and tread at each position. Mark all of them before cutting anything.
- Cut the plumb cut at the top and the level cut at the bottom — these are what let the stringer sit flat against the header and the landing.
- Take the drop off the bottom. Cut the base down by exactly one tread thickness, or the first step ends up a tread taller than every other one.
- Cut the notches with a circular saw, stopping short of the inside corner, and finish each corner with a handsaw. Over-cutting the corner removes material the stringer needs.
- Use the first stringer as the template for the rest. Never lay out the second one from scratch.
- Test fit before you cut the others. Set it in place and check that the treads come out level and the top and bottom sit tight.
Stair Mistakes to Avoid
- Measuring to the subfloor. Total rise is finished surface to finished surface. Tile, underlayment and flooring all count, and they are usually not there yet when you measure.
- Forgetting the drop. The bottom of the stringer comes down by one tread thickness. Skip it and the first riser is too tall by exactly that much.
- Cutting one tread too many. Treads are risers minus one, every time.
- Rounding the riser height. 7.71 in is the answer; 7-3/4 in "near enough" across fourteen steps accumulates into half an inch of error at the top.
- Not checking the run fits. A 9 ft rise needs nearly 11 ft of floor before any landing. Measure the space first.
- Over-cutting the notch corners. It weakens the stringer exactly where it carries load.
Frequently Asked Questions
How do I calculate stair rise and run?
Measure the total rise from finished floor to finished floor, then divide by your target riser height and round to a whole number of risers — that gives the riser count. Divide the total rise by that count for the actual riser height, which is what you cut. Treads are always one fewer than risers, so total run is treads × tread depth. A 108 in rise at a 7.5 in target gives 14 risers of 7.71 in, 13 treads, and 130 in of run.
Why is there one fewer tread than riser?
Because the top landing is the last tread. A flight climbing to a deck surface has a riser up onto that surface, but the deck itself is the walking surface — you do not build a tread there. Forgetting this is a classic stair layout error, and it shows up as one tread too many and a flight that lands proud of the floor.
What is the maximum riser height for stairs?
The IRC figure that most US jurisdictions adopt for residential stairs is 7-3/4 in maximum riser and 10 in minimum tread depth. Commercial stairs under the IBC are shallower. Your local amendments govern, so confirm with your building department before you cut — this calculator flags when your numbers fall outside the IRC figures but it cannot approve a design.
Why do all the risers have to be the same height?
People climb stairs by feel, not by looking. Once the first two steps set the rhythm, a riser that differs trips them. The IRC allows no more than 3/8 in between the tallest and shortest riser in a flight, which is tighter than most people expect and is the reason you divide the rise evenly instead of cutting a short step at the bottom.
How long a board do I need for a stair stringer?
The stringer length is the diagonal: the square root of total rise squared plus total run squared. For a 108 in rise and 130 in run that is 169 in, or 14 ft 1 in. Buy the next standard length up — a 16 ft board here — because the cut ends are angled and you lose length to the plumb cut at the top and the level cut at the bottom.
How many stringers do I need?
Three for a typical 36 in wide flight — one at each side and one in the middle — and a fourth if the stair is wider than about 36 in or the treads are thin. Spacing is driven by the tread material: 2x stock spans further than 5/4 decking, which sags between stringers set too far apart. Check the span the tread manufacturer publishes.
What is the drop on a stair stringer?
When the stringer sits on the bottom landing, the first riser ends up taller than the rest by the thickness of one tread — because the other risers are measured tread-surface to tread-surface. You fix it by cutting the bottom of the stringer down by exactly one tread thickness. This is the "drop", and skipping it is why a first step often feels wrong.
How steep should stairs be?
A flight built to a 7.5 in riser and a 10 in tread sits at about 37°, and a 7-3/4 by 10 stair is about 38°. Anything much past 40° feels like a ladder and usually means the riser is over the limit. If the angle is coming out too steep, the fix is more run, not taller risers.
How much space do stairs take up?
More than people plan for. A standard 8 ft ceiling gives roughly a 108 in total rise once the floor assembly is counted, which needs 14 risers and 130 in — nearly 11 ft — of floor length, before any landing at either end. Check the run fits before you commit to a riser height.
Does the tread nosing count in the run?
No. Total run is measured from the face of one riser to the face of the next, so the nosing overhang sits outside that figure. Nosing is added for footing comfort and is typically 3/4 to 1-1/4 in where treads are used, but it does not lengthen the stair. Enter the tread depth without it.
How much concrete do I need for poured steps instead?
That is a volume question rather than a layout one — use the Steps tab on our concrete calculator. A flight of solid steps is a staircase-shaped prism, so four steps hold ten riser-heights of concrete rather than four, which is why poured steps are so often short-ordered.
What headroom do stairs need?
The IRC residential figure is 6 ft 8 in measured vertically from the nosing line to whatever is above. It is the dimension most often missed on a basement stair cut into an existing floor, and it cannot be fixed after the opening is framed. Confirm the figure with your local building department.
Sources & Standards
- International Residential Code (ICC) — Residential construction requirements adopted by most US jurisdictions
Estimates for planning only. This calculator sizes material quantities. It does not size structural members, verify load paths, or confirm compliance with the code in your jurisdiction. Local requirements — frost depth, footing sizes, permits, and inspections — override anything here. Check with your local code enforcement office or building department before you build. They are the authority that inspects and signs off the work, they amend the model codes, and what they say overrides any figure on this page. For structural or safety-critical work, have the design checked by a licensed engineer or contractor as well. See our full method and assumptions.