An ice dam is a ridge of ice along the eaves that holds back melting snow. The water behind it can back up under the shingles and into the ceiling and walls. Ice dams form when heat from the house melts snow on the upper roof and the water refreezes at the cold edge, so the lasting fix is to keep that heat out of the attic. This guide covers why they form, the permanent fix in the order that matters, what to do about one that is leaking now, and where heat cable and eave membrane fit in.
What's in this guide
How an Ice Dam Forms
The Department of Energy’s Building America Solution Center says an ice dam needs three things: snow on the roof, a poorly air-sealed or poorly insulated attic, and freezing temperatures. It notes dams can form with as little as 2 in of snow on the roof.
University of Minnesota Extension describes the temperatures involved. The upper part of the roof surface sits above 32°F while the lower edge stays below it, averaged over days rather than hours, and the outside air has to be below freezing for the edge to stay cold. Snow melts on the warm upper roof, the water runs down, and it freezes again where the roof overhangs the wall and has no heat under it. Each thaw adds to the ridge, and the pool of water behind it grows.
Icicles are a warning sign. The DOE page says icicles often mean liquid water is building up behind the dam, where it can be drawn up under the shingles and cause leaks. A row of large icicles along an eave is worth a look in the attic and on the ceiling below.
Where the Heat Comes From
UMN Extension calls air leakage the major way heat reaches the roof in many homes. Warm indoor air rises through gaps in the top-floor ceiling and warms the underside of the roof deck. The common leak points and heat sources named by the DOE and UMN are:
- Recessed can lights and other ceiling light fixtures
- Gaps around electrical wiring and plumbing stacks
- Furnace flues and chimneys
- Attic hatches and pull-down stairs
- Dropped ceilings, open soffits over cabinets and the tops of interior walls (top plates)
- Exhaust fan housings, and exhaust ducts that end just above the roof
- Ceiling drywall seams
- Leaky or uninsulated heating ducts in the attic
- Knee walls in finished attics and skylights
Thin insulation adds to the problem by letting heat conduct straight through the ceiling, but a leaky ceiling with plenty of insulation can still cause ice dams because moving air carries heat past the insulation. UMN notes that sun alone causes the temperature difference only rarely.
The Permanent Fix, in Order
Both the DOE and UMN put the steps in the same order, and the order matters: insulation laid over an unsealed ceiling buries the leaks where they are hard to reach.
UMN adds a point that saves money: once the ceiling is sealed and insulated well, only a small amount of roof ventilation is needed, and it does not recommend powered attic fans for ice dams, which it says can cause attic moisture problems and unwanted negative pressure in the house. When you tighten a house, make sure fuel-burning appliances and exhaust fans still get the air they need to vent safely; a heating contractor can check this.
Work out attic insulation depth, bags and baffles
Attic Insulation Calculator βAttic Ventilation Numbers
The International Residential Code sets the vent area for a vented attic as 1 sq ft of net free area for every 150 sq ft of attic floor. It allows 1 per 300 when 40 to 50% of the vent area is high on the roof, within 3 ft of the ridge, with the rest low, and the code’s other conditions are met, which include a vapor retarder on the warm side of the ceiling in the coldest zones. Net free area is printed on each vent, usually in square inches.
| Attic Floor | At 1/150 | At 1/300 | High Vents at 1/300 (40–50%) |
|---|---|---|---|
| 1,000 sq ft | 6.67 sq ft (960 sq in) | 3.33 sq ft (480 sq in) | 192–240 sq in |
| 1,200 sq ft | 8 sq ft (1,152 sq in) | 4 sq ft (576 sq in) | 230–288 sq in |
| 1,500 sq ft | 10 sq ft (1,440 sq in) | 5 sq ft (720 sq in) | 288–360 sq in |
| 2,000 sq ft | 13.33 sq ft (1,920 sq in) | 6.67 sq ft (960 sq in) | 384–480 sq in |
A 1,200 sq ft attic needs 8 sq ft (1,152 sq in) of net free area at 1/150, or 4 sq ft (576 sq in) at 1/300. Check what your local code adopts; ventilation rules vary by edition and by climate zone.
What to Do About an Ice Dam Right Now
If water is already coming in, the goal is to drain the water behind the dam and reduce the snow feeding it. None of these steps fixes the cause.
- Rake the snow off the lower roof from the ground with a long-handled roof rake. UMN warns that a rake or broom can damage roofing, so pull gently and leave a thin layer rather than scraping to the shingles.
- Open a channel through the dam. UMN describes hosing a channel with tap water on a warm day, working upward from the lower edge of the dam, so the trapped water can drain. It also says the channel stops working within days.
- Do not chip at the ice with a hammer, hatchet or shovel. Shingles are brittle in the cold and break along with the ice.
- Stay off an icy roof. UMN warns that winter roof work, whether on the roof or from a ladder, risks injury and roof damage, and recommends leaving it to professionals. A ladder resting on an icy gutter can slide out from under you.
- Inside, dry the wet areas right away to limit mold. UMN advises not repairing ceilings and walls until they are fully dry, and doing the repair together with the attic fix, or the damage comes back next winter.
Expect more snow to stay on the roof after the fix. UMN notes that a well-insulated roof keeps its snow longer, and that a house built to current codes should carry it. If you are unsure about an older roof, check the plans or ask an engineer.
Heat Cable: A Stopgap, Not a Cure
Self-regulating heat cable laid in a zigzag along the eave, in the gutter and down the downspout keeps a path open for meltwater. It does not stop the melting that causes the dam. King Electric’s design guide says its cable is designed to remove ice, not accumulated snow, and will not keep snow from sliding off the roof.
It takes more cable than most people expect. King’s worked example, a 48 ft eave on a shingle roof with a 12 in overhang, 48 ft of gutter, one 22 ft downspout, two power connections and three splices, comes to 237.4 ft of cable, about five times the eave length (the heat cable calculator shows each line). Cable must be plugged into a ground-fault protected circuit and stay on the roof surface, never under the shingles.
Heat cable makes sense on a roof that keeps damming while you plan the attic work, or on a section that cannot be fixed from inside, such as the roof over a cathedral ceiling or a low porch roof.
Work out how much roof and gutter heat cable you need
Heat Cable Calculator βEave Membrane: The Backup Layer
A self-adhered ice barrier membrane under the shingles at the eaves seals around nails, so water backed up by a dam has a harder time getting through the roof deck. The DOE describes it as an added layer of protection should ice dams occur, not a way to prevent them. The IRC requires an ice barrier where ice has historically formed at the eaves, running from the roof edge to at least 24 in inside the exterior wall line.
Because that distance is measured to a point inside the wall, the membrane has to cover the overhang plus 24 in, measured up the slope. The overhang here is measured level, from the face of the wall out to the roof edge. Steeper roofs and deeper overhangs need more:
| Eave Overhang | 4/12 Pitch | 6/12 Pitch | 8/12 Pitch | 12/12 Pitch |
|---|---|---|---|---|
| None | 25.3 in | 26.8 in | 28.8 in | 33.9 in |
| 12 in | 37.9 in | 40.2 in | 43.3 in | 50.9 in |
| 24 in | 50.6 in | 53.7 in | 57.7 in | 67.9 in |
Membrane rolls are commonly 36 in wide, so a 12 in overhang on a 4/12 roof (37.9 in up the slope) already needs a second course or a wider roll. The membrane goes down when the roof is replaced; it is not something to add under existing shingles. The roofing calculator and the roof pitch calculator give the slope factor for your roof.
Ranked by value: seal the ceiling, insulate, ventilate, and use heat cable and membrane as protection while the attic work gets done or where it cannot be done.
Frequently Asked Questions
What causes ice dams?
Heat from the house melts snow on the upper roof, and the water refreezes at the cold eaves. The DOE says it takes snow on the roof, a poorly air-sealed or poorly insulated attic, and freezing temperatures. Air leaking through the top-floor ceiling is the main heat source in many homes.
How do I stop ice dams permanently?
In this order: air seal the ceiling, insulate the attic floor, then ventilate the roof from soffit to ridge with a baffle in every rafter bay. The DOE calls air sealing the most important step, and both the DOE and UMN Extension put it first.
Should I remove an ice dam myself?
Keep to what you can do from the ground. Rake snow off the lower roof gently with a roof rake, and on a warm day you can hose a channel through the dam, working up from the lower edge, so trapped water drains. Do not chip the ice or climb an icy roof; UMN recommends calling professionals for roof work in winter.
Does heat cable prevent ice dams?
It keeps a drainage path open through the dam, but it does not stop the melting that causes it. King Electric says its cable is designed to remove ice, not snow. Use it as a stopgap while you fix the attic, or on a section of roof the attic work cannot reach.
Do more attic vents stop ice dams?
Ventilation helps keep the roof deck cold, but it comes third. UMN Extension says that once the ceiling is sealed and insulated well, only a small amount of ventilation is needed, and it does not recommend powered attic fans for ice dams, which it says can cause attic moisture problems and unwanted negative pressure in the house.
How much attic ventilation do I need?
The IRC baseline is 1 sq ft of net free vent area per 150 sq ft of attic floor, or 1 per 300 when vents are split high and low and the code’s other conditions are met. A 1,200 sq ft attic needs 8 sq ft (1,152 sq in) at 1/150, or 4 sq ft at 1/300.
How much insulation stops ice dams?
ENERGY STAR recommends R-49 in zones 2 and 3 and R-60 in zones 4 through 8 for attics. Insulation only works with the air sealing done first, and it must not block the soffit vents, so install baffles at the eaves before blowing it in.
How far up the roof does ice and water shield go?
The IRC requires an ice barrier from the edge of the roof to at least 24 in inside the exterior wall line where ice has formed at the eaves. Measured up the slope, that is 37.9 in for a 12 in overhang on a 4/12 roof and 57.7 in for a 24 in overhang on an 8/12 roof, so most roofs need more than one 36 in course.
Are icicles a sign of an ice dam?
Often. The DOE says icicles are frequently a sign that liquid water is building up behind a dam, where it can be drawn under the shingles. Check the ceiling and the top of the exterior walls below a row of large icicles for stains or damp.
Can ice dams form on a roof with little snow?
Yes. The DOE notes ice dams can form with as little as 2 in of snow on the roof, as long as the upper roof is warm enough to melt it and the eaves stay below freezing.